Product description

When working with radioactive gamma sources, it is necessary to monitor working places, rooms or systems by measuring the current dose rate levels and compare these with limit values. The ALMO system was developed as a modular system for this purpose and can be composed application-specifically by various detector types and accessories like alarm lights and software.

Top

Downloads (PDF)

ALMO Prospekt   ALMO1 Prospekt
ALMO brochure
ALMO1 flyer
     
a

Versions

The ALMO system is a stationary dose rate meter which can be combined
with 1 to 6 external detectors for dose rate measurement.

  1. ALMO-1: Alarm monitor with connection for 1 external detector
  2. ALMO-3: Alarm monitor with connection for up to 3 external detectors
  3. ALMO-6: Alarm monitor with connection for up to 6 external detectors
ALMO-1:	Alarmmonitor zum Anschluss von 1 externem Detektor
ALMO-3:	Alarmmonitor zum Anschluss von bis zu 3 externen Detektoren
ALMO-6:	Alarmmonitor zum Anschluss von bis zu 6 externen Detektoren
 
Click on the images to get more details on the right.
a

ALMO-1: Alarm monitor with connection for 1 external detector

ALMO-1:	Alarmmonitor zum Anschluss von 1 externem Detektor

The ALMO-1 is a stand-alone dose rate measuring system for stationary use, for example monitoring of non-destructive test facilities.

Depending on the dose rate level, several detector types can be connected. The microprocessor-based measuring electronics show the measured dose rate on an LCD.

a

ALMO-3: Alarmmonitor zum Anschluss von bis zu 3 externen Detektoren

ALMO-3:	Alarmmonitor zum Anschluss von bis zu 3 externen Detektoren

The ALMO-3 system can be connected to max. 3 external detectors. It is possible to connect different detector types, e.g. type 18509 for system monitoring (high dose rate) and type 18550 for working place monitoring (measurement of some μSv/h) ) parallelly. 2 freely definable alarm thresholds can be set for each detector.
a

ALMO-6: Alarm monitor with connection for up to 6 external detectors

ALMO-6:	Alarmmonitor zum Anschluss von bis zu 6 externen Detektoren

For monitoring of large halls or laboratories, up to 6 external detectors can be connected to the ALMO-6 system. The maximum distance between ALMO and detectors is 100 m.

The ALMO-6 system can be linked to a central PC-system for measuring data logging and evaluation. In case of large area monitoring, several ALMO-6 systems can be linked. It is also possible to use additional displays.
a

Connectible detectors

For dose rate measurement, a range of detectors is available. In the following table, the main specifications of all detectors are summarized.


Typ Energy-
range
Measuring
range
Dimensions
Weight
GM-detector 18545 C 40 keV - 1,3 MeV 150 nSv/h - 200 μSv/h length 345 mm
diameter 25/40 mm
380 g
GM-detector 18550 C 40 keV - 1,3 MeV 1 μSv/h -
20 mSv/h
length 110 mm diameter 40 mm
150 g
GM-detector 18509 C 55 keV - 1,3 MeV 10 μSv/h -
1 Sv/h
lenght 110 mm diameter 40 mm
150 g
GM-detector 18529 C 70 keV - 1,3 MeV 100 μSv/h -
10 Sv/h
length 110 mm
diameter 40 mm
150 g
NaI-
NaI-scintillation detector 25B38
25 keV - 1,3 MeV 40 nSv/h -
200 μSv/h
length 38 mm
(acive area)
diameter 25 mm
200 g
a

Options

The following system options are available:

  1. Alarm units
  2. Software for measurement and data recording
  3. Additional measuring value display
Warneinheiten
Software zur Messung und Datenspeicherung
Zusätzliche Messwertanzeige
 
Click on the images to get more details on the right.
a

Alarm units

Software zur Messung und Datenspeicherung

Alarm units like the 3-level LED-lamp can be connected to all ALMO-systems for alarm visualization.
a

Software for measurement and data recording

Software zur Messung und Datenspeicherung

Software zur Messung und Datenspeicherung

All measurement data can be displayed graphically by the software for measurement and data storage.

For example, dose rate measurement values can be displayed in a curve, as a function of time. In addition, lamp symbols (green/yellow/red) can be shown during actual monitoring for a quick interpretation of the measurement values.
a

Additional measuring value display

Zusätzliche Messwertanzeige

Depending on the local circumstances it may be necessary to display the measuring value of one or more detectors at the measurement or monitoring place, apart from the central measurement display of the ALMO. The external measurement display offers a high comfort with task-specific parameter setting.